EOAM-1AG/2/hwEthoamClosePortAlarm_active: NNI or Remote UNI fault, the service UNI interface is closed by Ethernet OAM PortLink Function.(PhysicalIndex=[PhysicalIndex],ChassisId=[ChassisId],SlotId=[SlotId],CardId=[CardId],PortId=[PortId],PortDecrip =[PortDescrip],MepId=[MepId],UniName=[UniName]).
Parameter Name | Parameter Meaning |
---|---|
PhysicalIndex |
The Index of physical port. |
ChassisId |
Indicates the chassis number. |
SlotId |
Indicates the slot number. |
CardId |
Indicates the card number. |
PortId |
Indicates the port number. |
PortDescrip |
Indicates the description of port. |
MepId |
Indicates the Mep number. |
UniName |
The name of Uni interface. |
1.Check the status of Ethoam.If the Ethoam detect ccm lost or oam fail, then resume the Ethoam alm. - If the alarm is cleared, go to Step 4. - If the alarm is not cleared, go to Step 2. 2.Check the uni interface of rmep.If the uni interface down,then resume the broken. - If the alarm is cleared, go to Step 4. - If the alarm is not cleared, go to Step 3. 3.Collect alarm information, log information and configuration information, and then contact technical support personnel. 4.End.