EOAM-1AG/2/hwEthoamClosePortAlarm_active

Message

EOAM-1AG/2/hwEthoamClosePortAlarm_active: NNI or Remote UNI fault, the service UNI interface is closed by Ethernet OAM PortLink Function.(PhysicalIndex=[PhysicalIndex],ChassisId=[ChassisId],SlotId=[SlotId],CardId=[CardId],PortId=[PortId],PortDecrip =[PortDescrip],MepId=[MepId],UniName=[UniName]).

Description

The physical interface is disabled by Ethernet OAM.

Parameters

Parameter Name Parameter Meaning

PhysicalIndex

The Index of physical port.

ChassisId

Indicates the chassis number.

SlotId

Indicates the slot number.

CardId

Indicates the card number.

PortId

Indicates the port number.

PortDescrip

Indicates the description of port.

MepId

Indicates the Mep number.

UniName

The name of Uni interface.

Possible Causes

ETHOAM 1ag detect ccm lost or oam fail, or the uni interface of rmep is down .

Procedure

1.Check the status of Ethoam.If the Ethoam detect ccm lost or oam fail, then resume the Ethoam alm. - If the alarm is cleared, go to Step 4. - If the alarm is not cleared, go to Step 2. 2.Check the uni interface of rmep.If the uni interface down,then resume the broken. - If the alarm is cleared, go to Step 4. - If the alarm is not cleared, go to Step 3. 3.Collect alarm information, log information and configuration information, and then contact technical support personnel. 4.End.