DEVM/4/hwIfMonitorInputRateRising_active: Interface input flow bandwidth usage exceeded the trap threshold. (Interface=[IfIndex], BandWidthUsage=[hwSubIfInputRatePercentage], TrapThreshold=[hwSubIfInputRateThreshold], InterfaceName=[InterfaceName])
In VS mode, this log is supported only by the admin VS.
| Parameter Name | Parameter Meaning |
|---|---|
|
IfIndex |
Interface index . |
|
hwSubIfInputRatePercentage |
Input flow bandwidth usage. |
|
hwSubIfInputRateThreshold |
Trap threshold. |
|
InterfaceName |
Interface name. |
1.Run the display this interface command in the interface view to check whether the traffic volume threshold is proper for the actual service conditions.
2.Run the trap-threshold input-rate threshold_value command in the interface view to set a proper alarm threshold. Then, check whether the alarm is cleared.
3.Collect the trap, log, and configuration information, and then contact technical support personnel.
4.End.