DEVM/1/hwIfMonitorSdhErrorRising_active: The Sdh error is rising. (hwIfMonitorIndex=[hwIfMonitorIndex], hwIfMonitorSdhErrorStatistics=[hwIfMonitorSdhErrorStatistics], hwIfMonitorSdhErrorThreshold=[hwIfMonitorSdhErrorThreshold], hwIfMonitorSdhErrorInterval=[hwIfMonitorSdhErrorInterval], hwIfMonitorName=[hwIfMonitorName])
In VS mode, this log is supported only by the admin VS.
Parameter Name | Parameter Meaning |
---|---|
hwIfMonitorIndex |
Index of physical port. |
hwIfMonitorSdhErrorStatistics |
Sdh error statistics value only for B3. |
hwIfMonitorSdhErrorThreshold |
Sdh error alarm threshold. |
hwIfMonitorSdhErrorInterval |
Sdh error alarm interval time(unit is second),only for B3,default value is 10s and 0 is an invalid value. |
hwIfMonitorName |
Name of physical port. |
1.Replace the optical module and then check whether the fault is rectified.
2.Replace the optical fiber, and then check whether the fault is rectified.
3.Collect alarm information, log information and configuration information, and then contact technical support personnel.