DCNM/2/hwIpRanDcnNeNumberOverLoad_active

Message

DCNM/2/hwIpRanDcnNeNumberOverLoad_active: DCN NE number overload start. (NeNumber=[NeNumber])

In VS mode, this log is supported only by the admin VS.

Description

The number of NEs connected to the GNE exceeds the alarm threshold.

Parameters

Parameter Name Parameter Meaning

NeNumber

Indicates the NE quantity.

Possible Causes

The DCN NE number exceeds the setting threshold

Procedure

1. Run the display dcn ne-info command to check whether the number of entries in the DCN core routing table has exceeded the upper limit.

2. Run the display this command in the DCN view to check the alarm threshold for the number of NEs connected to the GNE.

3. Collect alarm information and configuration information, and then contact technical support personnel. Replan the DCN subnets or change the alarm threshold for the number of NEs connected to the GNE.

Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
< Previous topic Next topic >