IPFPM/2/hwIpfpmLossRatioExceed_clear

Message

IPFPM/2/hwIpfpmLossRatioExceed_clear: The loss ratio of IPFPM test instance was under the lower threshold in continuous five test intervals. (TestInstanceId=[InstanceId], AchId=[AchId], IpfpmMcpSeqNoHigh=[SeqNoHigh], IpfpmMcpSeqNoLow=[SeqNoLow], FlowType=[FlowType], ForwardPktLossRatio=[ForPktLossRatio], BackwardPktLossRatio=[BackPktLossRatio],InstDesc=[InstDesc])

Parameters

Parameter Name Parameter Meaning

InstanceId

IP FPM instance ID

AchId

Atomic closed hop ID

SeqNoHigh

32 most significant bits of the statistical period ID

SeqNoLow

32 least significant bits of the statistical period ID

FlowType

Target flow type

ForPktLossRatio

Packet loss rate for the forward target flow

BackPktLossRatio

Packet loss rate for the backward target flow

InstDesc

Specify description of test instance

Possible Causes

The network transmission quality becomes good, and the packet loss ratios within five consecutive measurement intervals are lower than the clear alarm threshold.

Procedure

This alarm is informational only, and no action is required.