IPFPM/3/hwIpfpmMultiOneDelayExceed_active

Message

IPFPM/3/hwIpfpmMultiOneDelayExceed_active: The one-way delay of one link in an IPFPM test instance exceeded the upper threshold over five consecutive statistical periods. (TestInstanceId=[InstanceId], AchId=[AchId], IpfpmMcpSeqNoHigh=[SeqNoHigh], IpfpmMcpSeqNoLow=[SeqNoLow], FlowType=[FlowType], SourceDCP=[SrcDcpId], SourceTLP=[SrcTlpId], DestinationDCP=[DstDcpId], DestinationTLP=[DstTlpId], OneDelay=[DelayValue])

Description

The one-way delay of one link in an IP FPM instance exceeded the upper threshold over five consecutive statistical periods.

Parameters

Parameter Name Parameter Meaning

InstanceId

IP FPM instance ID.

AchId

Atomic closed hop ID.

SeqNoHigh

32 most significant bits of the statistical period ID.

SeqNoLow

32 least significant bits of the statistical period ID.

FlowType

Target flow type.

SrcDcpId

Source Dcp Id.

SrcTlpId

Source Tlp Id.

DstDcpId

Destination Dcp Id.

DstTlpId

Destination Tlp Id.

DelayValue

One-way delay for the target flow.

Possible Causes

The one-way delay of one link in an IP FPM instance exceeded the upper threshold over five consecutive statistical periods.

Procedure

1. Check whether abnormal traffic existed on the network when the trap was generated.

  • If abnormal traffic existed on the network, go to Step 2.
  • If no abnormal traffic existed on the network, go to Step 3.

2. Check whether the abnormal traffic was caused by misoperations.

  • If the abnormal traffic was caused by misoperations, go to Step 3.
  • If the abnormal traffic was not caused by misoperations, go to Step 6.

3. Delete the misoperation configurations and check whether the trap persists.

  • If the trap persists, go to Step 4.
  • If the trap is cleared, go to Step 7.

4. Check whether the link status was stable when the trap was generated.

  • If the link status was stable, go to Step 6.
  • If the link status was unstable, go to Step 5.

5. Check the problem that caused the unstable link status, resolve the problem, and check whether the trap persists.

  • If the trap persists, go to Step 6.
  • If the trap is cleared, go to Step 7.

6. Collect alarm information and configuration information, and then contact technical support personnel.

7. End.