IPFPM/2/hwIpfpmOneDelayExceed_clear

Message

IPFPM/2/hwIpfpmOneDelayExceed_clear: The one-way delay of IPFPM test instance was under the lower threshold in continuous five test intervals. (TestInstanceId=[InstanceId], AchId=[AchId], IpfpmMcpSeqNoHigh=[SeqNoHigh], IpfpmMcpSeqNoLow=[SeqNoLow], FlowType=[FlowType], ForwardOneDelay=[ForDelayValue], BackwardOneDelay=[BackDelayValue], InstDesc=[InstDesc])

Parameters

Parameter Name Parameter Meaning

InstanceId

IP FPM instance ID

AchId

Atomic closed hop ID

SeqNoHigh

32 most significant bits of the statistical period ID

SeqNoLow

32 least significant bits of the statistical period ID

FlowType

Target flow type

ForDelayValue

One-way delay for the forward target flow

BackDelayValue

One-way delay for the backward target flow

InstDesc

Specify description of test instance

Possible Causes

The network transmission quality becomes good.

Procedure

This alarm is informational only, and no action is required.

Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
< Previous topic Next topic >