FEI_L2/4/hwL2ProtoTunnelDropThresholdAlarm_active

Message

FEI_L2/4/hwL2ProtoTunnelDropThresholdAlarm_active: The number of the protocol transmit on the port reach the drop threshold.(IfName=[ifname], ProtocolName=[protocolname], DropThreshold=[dropthreshold])

In VS mode, this log is supported only by the admin VS.

Description

The number of protocol packets that were transparently transmitted at Layer 2 reached the drop threshold.

Parameters

Parameter Name Parameter Meaning

ifname

Interface name.

protocolname

Protocol name.

dropthreshold

Threshold for dropping protocol packets transparently transmitted at Layer 2.

Possible Causes

The number of the protocol transmit on the port reach the drop threshold.

Procedure

1. Run the l2protocol-tunnel drop-threshold number all command to increase the maximum number of drop threshold. Check whether the alarm is cleared.

  • If the alarm is cleared, go to Step 3.
  • If the alarm persists, go to Step 2.

2.Collect trap, log, and configuration information, and contact technical support personnel.

3.End.

Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
< Previous topic Next topic >