LACP/2/hwLacpPartialLinkLoss_active

Message

LACP/2/hwLacpPartialLinkLoss_active: Link bandwidth lost partly. (TrunkIndex=[TrunkIndex], TrunkIfIndex=[TrunkIfIndex], TrunkId=[TrunkId], TrunkName=[TrunkName], Reason=[ReasonCode])

Description

Part of the bandwidth of a link was lost.

Parameters

Parameter Name Parameter Meaning

TrunkIndex

Index of a trunk

TrunkIfIndex

Index of a trunk interface

TrunkId

ID of a trunk interface

TrunkName

Name of a trunk interface

ReasonCode

Reason why part of the bandwidth of a link was lost or resumed.

Possible Causes

The number of the Eth-trunk member links that can be selected is smaller than the lower threshold value.

Procedure

1. Run the display interface brief command to check whether the interface is Down.

  • If so, go to Step 2.
  • If not, go to Step 4.

2. Run the undo shutdown command to check whether the alarm is cleared.

  • If so, go to Step 10.
  • If not, go to Step 3.

3. Check whether the physical link is faulty.

  • If so, go to Step 7.
  • If not, go to Step 4.

4. Run the display eth-trunk [ trunk-id [ interface interface-type interface-number | verbose ] ] command to check whether there are member interfaces in the LAG.

  • If so, go to Step 5.
  • If not, go to Step 8.

5. Run the display trunkmembership eth-trunk trunk-id command to check whether the lower threshold for Eth-Trunk member links is set in the LAG; whether the number of Eth-Trunk member links that are successfully negotiated is smaller than the lower threshold for the Eth-Trunk member links that can be Up.

  • If so, go to Step 6.
  • If not, go to Step 9.

6. In the Eth-Trunk interface view, run the least active-linknumber link-number command to correctly set the lower threshold of Trunk member links that can be Up. Then, check whether the alarm is cleared.

  • If so, go to Step 10.
  • If not, go to Step 9.

7. Repair the physical link and then check whether the alarm is cleared.

  • If so, go to Step 10.
  • If not, go to Step 4.

8. Run the eth-trunk trunk-id command in the interface view and add the current Ethernet interface to the Eth-Trunk interface as required. Then, check whether the alarm is cleared.

  • If so, go to Step 10.
  • If not, go to Step 5.

9. Collect alarm information and configuration information, and then contact technical support personnel.

10. End.