DEVM/1/hwLaserNoFited_active

Message

DEVM/1/hwLaserNoFited_active: The laser not installed alarm occurred. (EntityPhysicalIndex=[hwEntityPhysicalIndex], EntityPhysicalIndex=[entPhysicalIndex], EntPhysicalName=[entPhysicalName])

In VS mode, this log is supported only by the admin VS.

Description

The laser not installed alarm.

Parameters

Parameter Name Parameter Meaning

hwEntityPhysicalIndex

Index of physical port.

entPhysicalIndex

Index of physical port.

entPhysicalName

Entity physical name.

Possible Causes

Cause 1: The optical interface was enabled, but no optical module was installed for the optical interface.

Cause 2: The optical module or board was faulty. As a result, the optical module cannot be checked.

Procedure

1.Check whether the optical module is installed.

  • If the alarm is cleared, go to End.
  • If the alarm is not cleared, go to Step 2.

3.Install the optical module. Then check whether the alarm is cleared.

  • If the alarm is cleared, go to End.
  • If the alarm is not cleared, go to Step 3.

3.Collect alarm information, log information and configuration information, and then contact technical support personnel.