DEVM/1/hwLaserNoFited_active: The laser not installed alarm occurred. (EntityPhysicalIndex=[hwEntityPhysicalIndex], EntityPhysicalIndex=[entPhysicalIndex], EntPhysicalName=[entPhysicalName])
In VS mode, this log is supported only by the admin VS.
Parameter Name | Parameter Meaning |
---|---|
hwEntityPhysicalIndex |
Index of physical port. |
entPhysicalIndex |
Index of physical port. |
entPhysicalName |
Entity physical name. |
Cause 1: The optical interface was enabled, but no optical module was installed for the optical interface.
Cause 2: The optical module or board was faulty. As a result, the optical module cannot be checked.
1.Check whether the optical module is installed.
3.Install the optical module. Then check whether the alarm is cleared.
3.Collect alarm information, log information and configuration information, and then contact technical support personnel.