MFLP/4/hwMflpBdAcBlock_active

Message

MFLP/4/hwMflpBdAcBlock_active: The AC interface turned to block state. (BD=[bdid], ACInterfaceName=[acifname], BlockTime=[blocktime], BlockReason=[blockreason], DetectMAC=[mac])

Description

An AC-side interface is blocked.

Parameters

Parameter Name Parameter Meaning

bdid

Bridge domain ID

acifname

AC-side interface name

blocktime

Blocking time

blockreason

Reason for the blocking

mac

Detected MAC address

Possible Causes

  • Cause 1: The AC has been blocked for BD loop, and the AC has already been permanently blocked.
  • Cause 2: The AC has been blocked for BD loop, and the loop has already been punished times times.

Procedure

  • Cause 1: The AC has been blocked for BD loop, and the AC has already been permanently blocked.

    1. Run the display current-configuration command to check whether the loopback local command is configured on AC-side interfaces corresponding to the BD.

    • If the loopback local command is configured on AC-side interfaces corresponding to the BD, delete the command configuration and check whether the alarm is cleared. If the alarm persists, go to Step 2.
    • If the loopback local command is not configured on AC-side interfaces corresponding to the BD, go to Step 2.

    2. Log in to the device and run the reset loop-detect eth-loop bridge-domain bd-id { all | interface interfacetype interfacenumber } command to unblock the PW and check whether hwMflpAcResume is reported. If hwMflpAcResume is not reported, go to Step 3.

    3. Collect alarm information and configuration information, and then contact technical support personnel.

  • Cause 2: The AC has been blocked for BD loop, and the loop has already been punished times times.

    1. Run the display current-configuration command to check whether the loopback local command is configured on AC-side interfaces corresponding to the BD.

    • If the loopback local command is configured on AC-side interfaces corresponding to the BD, delete the command configuration and check whether the alarm is cleared. If the alarm persists, go to Step 2.
    • If the loopback local command is not configured on AC-side interfaces corresponding to the BD, go to Step 2.

    2. Check whether the AC-side interface recovers after the block-time specified in the loop-detect eth-loop command expires. If the AC-side interface does not recover, go to Step 3.

    3. Collect alarm information and configuration information, and then contact technical support personnel.

Copyright © Huawei Technologies Co., Ltd.