MPLS_LSPM/3/hwMplsOamBDI_active: The tunnel receives a BDI alarm. (SessionTunnelId=[SessionTunnelId], LocalLspId=[LocalLspId], IngressLsrId=[IngressLsrId], EgressLsrId=[EgressLsrId], IfIndex=[OutIfIndex], TunnelName=[TunnelName], SignalingProtocol=[SgnlPrtcl], IfName=[OutIfName], SignalledTunnelName=[SignalledTunnelName])
Parameter Name | Parameter Meaning |
---|---|
SessionTunnelId |
Tunnel ID |
LocalLspId |
Local LSP ID |
IngressLsrId |
ID of the ingress LSR |
EgressLsrId |
ID of the egress LSR |
OutIfIndex |
Index of the interface |
TunnelName |
Tunnel name |
SgnlPrtcl |
Tunneling protocol |
OutIfName |
The name of the interface |
SignalledTunnelName |
Tunnel alias. |
1. Run the display interface command to check whether any physical interface connected to the MPLS tunnel is shut down.
2. Run the undo shutdown command to enable the physical interface. Then check whether the alarm is cleared.
3. If all configurations are correct, the MPLS tunnel is faulty. Then go to Step 4.
4. Collect the trap information, log information, and configuration information, and then Collect alarm information and configuration information, and then contact technical support personnel..
5. End.