MPLS_LSPM/3/hwMplsOamExcess_active: The tunnel receives an Excess alarm. (SessionTunnelId=[SessionTunnelId], LocalLspId=[LocalLspId], IngressLsrId=[IngressLsrId], EgressLsrId=[EgressLsrId], TunnelName=[TunnelName], SignalingProtocol=[SgnlPrtcl], SignalledTunnelName=[SignalledTunnelName])
Parameter Name | Parameter Meaning |
---|---|
SessionTunnelId |
Tunnel ID |
LocalLspId |
Local LSP ID |
IngressLsrId |
ID of the ingress LSR |
EgressLsrId |
ID of the egress LSR |
TunnelName |
Tunnel name |
SgnlPrtcl |
Tunneling protocol |
SignalledTunnelName |
Tunnel alias. |
1. The tunnels were configured incorrectly. Multiple tunnels had the same labels and IDs configured.
2. Physical links were incorrectly connected.
1. Run the display current-configuration command to check whether the specified OAM detection periods are the same.
2. Re-set the OAM detection periods on both ends. Then check whether MPLS_LSPM_1.3.6.1.4.1.2011.5.25.121.2.1.35 hwMplsOamExcessRecovery is reported.
3. Collect the trap information, log information, and configuration information, and then Collect alarm information and configuration information, and then contact technical support personnel..
4. End.