MPLS_LSPM/2/hwMplsOamPeriod_active: The tunnel receives a period inconsistency alarm. (SessionTunnelId=[SessionTunnelId], LocalLspId=[LocalLspId], IngressLsrId=[IngressLsrId], EgressLsrId=[EgressLsrId], TunnelName=[TunnelName], SignalingProtocol=[SgnlPrtcl], SignalledTunnelName=[SignalledTunnelName])
Parameter Name | Parameter Meaning |
---|---|
SessionTunnelId |
Tunnel ID |
LocalLspId |
Local LSP ID |
IngressLsrId |
ID of the ingress LSR |
EgressLsrId |
ID of the egress LSR |
TunnelName |
Tunnel name |
SgnlPrtcl |
Tunneling protocol |
SignalledTunnelName |
Tunnel alias. |
1. Run the display current-configuration command to check whether the CC detection periods of the local and peer ends are the same.
2. Configure a same CC detection period for the local and peer ends.
3. Collect the trap information, log information, and configuration information, and then Collect alarm information and configuration information, and then contact technical support personnel..
4. End.