MPLS_LSPM/2/hwMplsOamUnknown_active: The tunnel receives an Unknown alarm. (SessionTunnelId=[SessionTunnelId], LocalLspId=[LocalLspId], IngressLsrId=[IngressLsrId], EgressLsrId=[EgressLsrId], TunnelName=[TunnelName], SignalingProtocol=[SgnlPrtcl], SignalledTunnelName=[SignalledTunnelName])
Parameter Name | Parameter Meaning |
---|---|
SessionTunnelId |
Tunnel Id |
LocalLspId |
Local Lsp Id |
IngressLsrId |
Ingress Lsr Id |
EgressLsrId |
Egress Lsr Id |
TunnelName |
Tunnel Interface Name |
SgnlPrtcl |
Tunnel Signal Protocol: - 1: RSVP - 2: STATIC - 3: CRSTATIC PTN7900,PTN9X0: - 1: RSVP - 2: STATIC - 3: CRSTATIC - 4: SEGMENT_ROUTING |
SignalledTunnelName |
User-Defined Tunnel Name |
Tunnel OAM configurations were different on the source and sink NEs of a tunnel. The possible cause was that the detection packet type or detection period may be set incorrectly.
1.Run the display mpls oam ingress and display mpls oam egress commands to check whether OAM detection configurations on both ends are the same. - If so, go to Step 3. - If not, go to Step 2. 2.Reconfigure the OAM function on both ends. Then check whether MPLS_LSPM_1.3.6.1.4.1.2011.5.25.121.2.1.41 hwMplsOamUnknownRecovery is reported.. - If so, go to Step 4. - If not, go to Step 3. 3.Collect the alarm, log, and configuration information, and contact technical support personnel. 4.End.