MPLS_LSPM/2/hwMplsOamUnknown_active

Message

MPLS_LSPM/2/hwMplsOamUnknown_active: The tunnel receives an Unknown alarm. (SessionTunnelId=[SessionTunnelId], LocalLspId=[LocalLspId], IngressLsrId=[IngressLsrId], EgressLsrId=[EgressLsrId], TunnelName=[TunnelName], SignalingProtocol=[SgnlPrtcl], SignalledTunnelName=[SignalledTunnelName])

Description

An unknown error occurred on an MPLS tunnel.

Parameters

Parameter Name Parameter Meaning

SessionTunnelId

Tunnel Id

LocalLspId

Local Lsp Id

IngressLsrId

Ingress Lsr Id

EgressLsrId

Egress Lsr Id

TunnelName

Tunnel Interface Name

SgnlPrtcl

Tunnel Signal Protocol: - 1: RSVP - 2: STATIC - 3: CRSTATIC PTN7900,PTN9X0: - 1: RSVP - 2: STATIC - 3: CRSTATIC - 4: SEGMENT_ROUTING

SignalledTunnelName

User-Defined Tunnel Name

Possible Causes

Tunnel OAM configurations were different on the source and sink NEs of a tunnel. The possible cause was that the detection packet type or detection period may be set incorrectly.

Procedure

1.Run the display mpls oam ingress and display mpls oam egress commands to check whether OAM detection configurations on both ends are the same. - If so, go to Step 3. - If not, go to Step 2. 2.Reconfigure the OAM function on both ends. Then check whether MPLS_LSPM_1.3.6.1.4.1.2011.5.25.121.2.1.41 hwMplsOamUnknownRecovery is reported.. - If so, go to Step 4. - If not, go to Step 3. 3.Collect the alarm, log, and configuration information, and contact technical support personnel. 4.End.