TPOAM/4/hwMplsTpOamRemoteDefectIndication: RDI alarm start. (MegId=[MegId], MegId=[Meg_Id], MeIndex=[MeIndex], MeType=[MeType], MeDirection=[MeDirection], IfName=[IfName], PeerIP=[PeerIP], VcId=[VcId], VcType=[VcType], RemoteIp=[RemoteIp], Ttl=[Ttl], MepId=[MepId], RemoteMepId=[RemoteMepId], LspName=[LspName], VsiName=[VsiName])
Parameter Name | Parameter Meaning |
---|---|
MegId |
Name of a MEG |
Meg_Id |
Name of a MEG |
MeIndex |
Index of an ME |
MeType |
ME type:
|
MeDirection |
Tunnel type for an ME:
|
IfName |
Interface name |
PeerIP |
Peer IP address |
VcId |
VC ID |
VcType |
VC type |
RemoteIp |
IP address of an RMEP |
Ttl |
TTL value |
MepId |
Local ME ID |
RemoteMepId |
RMEP ID |
LspName |
LSP name |
VsiName |
VSI name |
The RMEP detected an LOC alarm and notified the MEP of the LOC alarm. Then the MEP generated an RDI alarm.
1. Run the display interface command to check whether any physical interface connected to the MPLS TE tunnel is shut down.
2. Run the undo shutdown command to enable the physical interface, and check whether the alarm is cleared.
3. Run the display mpls-tp oam meg command to check whether the MEP is enabled to receive CCMs and the RMEP is enabled to send CCMs in the MEG.
4. Enable the MEP to receive CCMs, and enable the RMEP to send CCMs. Then check whether the alarm is cleared.
5. Collect log information and configuration information, and then contact technical support personnel.
6. End.