TPOAM/4/hwMplsTpOamRemoteDefectIndication

Message

TPOAM/4/hwMplsTpOamRemoteDefectIndication: RDI alarm start. (MegId=[MegId], MegId=[Meg_Id], MeIndex=[MeIndex], MeType=[MeType], MeDirection=[MeDirection], IfName=[IfName], PeerIP=[PeerIP], VcId=[VcId], VcType=[VcType], RemoteIp=[RemoteIp], Ttl=[Ttl], MepId=[MepId], RemoteMepId=[RemoteMepId], LspName=[LspName], VsiName=[VsiName])

Description

TP OAM detected a remote fault.

Parameters

Parameter Name Parameter Meaning

MegId

Name of a MEG

Meg_Id

Name of a MEG

MeIndex

Index of an ME

MeType

ME type:

  • 1: PW VLL
  • 2: PW VSI
  • 3: TE -CR LSP
  • 4: Section
  • 5: Associate

MeDirection

Tunnel type for an ME:

  • ingress
  • egress
  • dual

IfName

Interface name

PeerIP

Peer IP address

VcId

VC ID

VcType

VC type

RemoteIp

IP address of an RMEP

Ttl

TTL value

MepId

Local ME ID

RemoteMepId

RMEP ID

LspName

LSP name

VsiName

VSI name

Possible Causes

The RMEP detected an LOC alarm and notified the MEP of the LOC alarm. Then the MEP generated an RDI alarm.

Procedure

1. Run the display interface command to check whether any physical interface connected to the MPLS TE tunnel is shut down.

  • If any physical interface connected to the MPLS TE tunnel is shut down, go to Step 2.
  • If no physical interface connected to the MPLS TE tunnel is shut down, go to Step 3.

2. Run the undo shutdown command to enable the physical interface, and check whether the alarm is cleared.

  • If the alarm is cleared, go to Step 6.
  • If the alarm is not cleared, go to Step 3.

3. Run the display mpls-tp oam meg command to check whether the MEP is enabled to receive CCMs and the RMEP is enabled to send CCMs in the MEG.

  • If the MEP is enabled to receive CCMs and the RMEP is enabled to send CCMs, go to Step 5.
  • If the MEP is not enabled to receive CCMs and the RMEP is not enabled to send CCMs, go to Step 4.

4. Enable the MEP to receive CCMs, and enable the RMEP to send CCMs. Then check whether the alarm is cleared.

  • If the alarm is cleared, go to Step 6.
  • If the alarm is not cleared, go to Step 5.

5. Collect log information and configuration information, and then contact technical support personnel.

6. End.