DEVM/1/hwOpticalInvalid_active-136217

Message

DEVM/1/hwOpticalInvalid_active: The optical module failed completely. (EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityTrapFaultID=136217, ReasonDescription=The temperature sensor of the Smart-Clock module was faulty.)

Description

The optical module failed completely.

Parameters

Parameter Name Parameter Meaning

EntityPhysicalIndex

Index of the physical entity.

EntPhysicalIndex

Index of the physical entity.

EntPhysicalName

Name of the physical entity.

EntityTrapFaultID

Error code.

ReasonDescription

Indicates the description of the possible cause.

Possible Causes

The temperature sensor of the Smart-Clock module was faulty.

Procedure

1. Reset the Smart-Clock module and check if the alarm is cleared.

  • If the alarm is cleared, go to Step 4.
  • If the alarm persists, go to Step 2.

2. Replace the Smart-Clock module and check if the alarm is cleared.

  • If the alarm is cleared, go to Step 4.
  • If the alarm persists, go to Step 3.

3. Collect trap, log, and configuration information, and contact technical support.

4. End.

Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
< Previous topic Next topic >