DEVM/1/hwOpticalInvalid_active: The optical module failed completely. (EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityTrapFaultID=136226, ReasonDescription=The receiving total power of the optical module is too low.)
Parameter Name | Parameter Meaning |
---|---|
EntityPhysicalIndex |
Index of the physical entity. |
EntPhysicalIndex |
Index of the physical entity. |
EntPhysicalName |
Name of the physical entity. |
EntityTrapFaultID |
Error code. |
ReasonDescription |
Indicates the description of the possible cause. |
1. Run the display interface command in the user view to check whether the input optical power (Rx Power) on the current interface is in the normal range. If the Rx power is in the normal range, go to Step 4.
2. Check whether the fiber is faulty. If so, replace the fiber.
3. Replace the optical module on the local interface. If the alarm persists after the optical module is replaced, go to Step 4.
4. Collect trap, log, and configuration information, and contact technical support.
5. End.