DEVM/1/hwOpticalInvalid_active: The optical module failed completely. (EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityTrapFaultID=136233, ReasonDescription=The Smart-Clock module failed to obtain leap second information in Single-GLONASS mode or GPS-GLONASS mode.)
Parameter Name | Parameter Meaning |
---|---|
EntityPhysicalIndex |
Index of the physical entity. |
EntPhysicalIndex |
Index of the physical entity. |
EntPhysicalName |
Name of the physical entity. |
EntityTrapFaultID |
Error code. |
ReasonDescription |
Indicates the description of the possible cause. |
The Smart-Clock module failed to obtain leap second information in Single-GLONASS mode or GPS-GLONASS mode.
1. Run the smart-clock gnss-model command in the GE-interface view to switch to the other mode(GPS, BEIDOU, GPS-BEIDOU). Then check whether the alarm is cleared.
2. Run the smart-clock leap command in the GE-interface view to configure leap second information. Then check whether the alarm is cleared.
3. Collect trap, log, and configuration information, and contact technical support.
4. End.