DEVM/1/hwOpticalInvalid_clear

Message

DEVM/1/hwOpticalInvalid_clear: The optical module resumed from total failure. (EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityTrapFaultID=[EntityTrapFaultID],ReasonDescription=[ReasonDescription])

Parameters

Parameter Name Parameter Meaning

EntityPhysicalIndex

Index of the physical entity.

EntPhysicalIndex

Index of the physical entity.

EntPhysicalName

Name of the physical entity.

EntityTrapFaultID

Error code.

ReasonDescription

Indicates the description of the possible cause.

Possible Causes

  • Cause 136192:The optical module worked normally.
  • Cause 136193:The output of the optical module was restored to normal.
  • Cause 136194:The output of the optical module was restored to normal.
  • Cause 136195:The input of the optical module was restored to normal.
  • Cause 136196:The input of the optical module was restored to normal.
  • Cause 136197:The voltage of the optical module was restored to normal.
  • Cause 136198:The voltage of the optical module was restored to normal.
  • Cause 136199:The bias current of the optical module was restored to normal.
  • Cause 136200:The bias current of the optical module was restored to normal.
  • Cause 136201:The temperature of the optical module was restored to normal.
  • Cause 136202:The temperature of the optical module was restored to normal.
  • Cause 136204:The optical module laser was restored to normal.
  • Cause 136205:The PLD or Flash initializatiaon was restored to normal.
  • Cause 136206:The power supply was restored to normal.
  • Cause 136207:The CFP checksum was restored to normal.
  • Cause 136208:The I2C interface of the Smart-Clock module was restored to normal.
  • Cause 136209:The interface of the PLL chip of the Smart-Clock module was restored to normal.
  • Cause 136210:The GPS chip of the Smart-Clock module was restored to normal.
  • Cause 136211:The memory chip of the Smart-Clock module was restored to normal.
  • Cause 136212:The SERDES interface of the Smart-Clock module was restored to normal.
  • Cause 136213:The internal 1PPS signals of the Smart-Clock module are normal.
  • Cause 136214:The internal clock source signals of the Smart-Clock module are normal.
  • Cause 136215:The system clock of the Smart-Clock module is normal.
  • Cause 136216:The voltage of the Smart-Clock module is normal.
  • Cause 136217:The temperature sensor of the Smart-Clock module is normal.
  • Cause 136218:The antenna of the Smart-Clock module is normal.
  • Cause 136219:The temperature of the Smart-Clock module was restored to normal.
  • Cause 136225:The receiving total power of the optical module was restored to normal.
  • Cause 136226:The receiving total power of the optical module was restored to normal.
  • Cause 136227:A component on the MSA's private register module was restored to normal.
  • Cause 136228:The MSA's private register module was restored to normal.
  • Cause 136229:The optical module resumed from total failure.
  • Cause 136230:The optical module connected abnormally.
  • Cause 136232:Enable fec-eth on the port.
  • Cause 136233:The Smart-Clock module successfully obtained leap second information in Single-GLONASS mode or GPS-GLONASS mode.
  • Cause 136234:The start-up of GNSS chip in Smart-Clock module recoverd.

Procedure

This trap message is informational only, and no action is required.