DEVM/4/hwOpticalTunableNotMatch_active: Configuration collision occurred between wavelength setting and untunable optical module. (EntityPhysicalIndex=[hwEntityPhysicalIndex], EntPhysicalIndex=[entPhysicalIndex], EntPhysicalName=[entPhysicalName], EntityTrapFaultID=[hwEntityTrapFaultID])
Configuration collision occurred between wavelength setting and untunable optical module.
Parameter Name | Parameter Meaning |
---|---|
hwEntityPhysicalIndex |
Index of physical port. |
entPhysicalIndex |
Index of physical port. |
entPhysicalName |
Name of the physical entity. |
hwEntityTrapFaultID |
Error code. |
A wavelength-tunable optical module is configured, whereas a wavelength-fixed one is installed.
1. Run the display this command in a specified interface view and check whether the wavelength is configured.
2. Run the display this interface command in a specified interface view and check whether the center wavelength of the optical module is tunable.
3. Replace the optical module and re-install the wavelength-tunable optical module. Alternatively, run the undo wavelength command to delete the center wavelength. Check whether the alarm is cleared.
4. Collect alarm information, log information and configuration information, and then contact technical support personnel.