DEVM/1/hwOutputErrorAlarm_active

Message

DEVM/1/hwOutputErrorAlarm_active: Output error alarm.(hwPhysicalPortIfIndex=[hwPhysicalPortIfIndex],BoardID=[hwPhysicalPortInSlot],CardID=[hwPhysicalPortInCard],PortID=[hwPhysicalPortInPort],InterfaceName=[hwPhysicalPortName])

Description

An alarm is generated when the number of alarms is set higher than the set time.

Parameters

Parameter Name Parameter Meaning

hwPhysicalPortIfIndex

Interface index(es) of physical port(s) present on the device.

hwPhysicalPortInSlot

Slot ID

hwPhysicalPortInCard

Card ID

hwPhysicalPortInPort

Port ID

hwPhysicalPortName

Port name

Possible Causes

  • Cause 1: The optical module failed.
  • Cause 2: The optical fiber failed.

Procedure

1.Replace the optical module and check whether the alarm is cleared.

  • If so, go to Step 4.
  • If not, go to Step 2.

2.Replace the fiber, check whether the alarm is cleared.

  • If so, go to Step 4.
  • If not, go to Step 3.

3.Collect the alarm information, log information, and configuration information, and then contact technical support personnel.

4.End.