PIC/2/hwPhysicalPortBip8SdError_active

Message

PIC/2/hwPhysicalPortBip8SdError_active: BIP8 SD alarm. (hwPhysicalPortIfIndex=[hwPhysicalPortIfIndex],hwPhysicalPortName="[hwPhysicalPortName]",hwPhysicalPortBIP8SDErrorThreshold=[hwPhysicalPortBIP8SDErrorThreshold])

In VS mode, this log is supported only by the admin VS.

Description

BIP8 SD alarm.

Parameters

Parameter Name Parameter Meaning

hwPhysicalPortIfIndex

Index of physical port.

hwPhysicalPortName

Name of physical port.

hwPhysicalPortBIP8SDErrorThreshold

BIP8-SD error alarm threshold.

Possible Causes

  • Cause 0: The optical module failed.
  • Cause 1: The optical fiber failed.

Procedure

1.Replace the optical module and check whether the alarm is cleared.

  • If the alarm is cleared, go to End.
  • If the alarm persists, go to Step 2.

2.Replace the optical fiber and check whether the alarm is cleared.

  • If the alarm is cleared, go to End.
  • If the alarm persists, go to Step 3.

3.Collect alarm information, log information and configuration information, and then contact technical support personnel.

4.End.

Copyright © Huawei Technologies Co., Ltd.