DEVM/2/hwPhysicalPortCrcError_active: Crc error alarm.(hwPhysicalPortIfIndex=[hwPhysicalPortIfIndex],hwPhysicalPortName=[hwPhysicalPortName],hwPhysicalPortCrcErrorStatistics=[hwPhysicalPortCrcErrorStatistics],hwPhysicalPortCrcErrorHighThreshold=[hwPhysicalPortCrcErrorHighThreshold],hwPhysicalPortCrcErrorLowThreshold=[hwPhysicalPortCrcErrorLowThreshold],hwPhysicalPortCrcErrorInterval=[hwPhysicalPortCrcErrorInterval])
In VS mode, this log is supported only by the admin VS.
Parameter Name | Parameter Meaning |
---|---|
hwPhysicalPortIfIndex |
Interface index(es) of physical port(s) present on the device. |
hwPhysicalPortName |
Interface name of physical port(s) present on the device. |
hwPhysicalPortCrcErrorStatistics |
Crc error statistics value. |
hwPhysicalPortCrcErrorHighThreshold |
Crc error alarm high threshold. |
hwPhysicalPortCrcErrorLowThreshold |
Crc error alarm low threshold. |
hwPhysicalPortCrcErrorInterval |
Crc error alarm interval time(unit is second). |
1.Replace the optical module and check whether the alarm is cleared.
2.Replace the fiber, check whether the alarm is cleared.
3.Collect the alarm information, log information, and configuration information, and then contact technical support personnel.
4.End.