PTP/4/hwPtpAcrSyncBad_active: 1588 ACR synchronization state is bad. (State=[State])
In VS mode, this log is supported only by the admin VS.
Parameter Name | Parameter Meaning |
---|---|
State |
State of synchoronization. values: normal(0). abnormal(1). |
Cause 1: The frequency offset of the traced source in synchronization Ethernet was too great.
Cause 2: The received timestamp was incorrect in 1588v2 frequency synchronization mode.
Cause 3: The DSP internal frequency control word exceeded +/-10 ppm.
1. Run the display clock source command to check whether the current system trace source is PTP.
2. Run the display current-configuration command to check whether PTP configurations need to be changed.
3. Reconfigure the local PTP attributes. Then check whether the alarm is cleared.
4. Run the display clock config command to check whether clock source configurations need to be changed.
5. Reconfigure the local clock source attributes. Then check whether the alarm is cleared.
6. Collect the alarm information, log information, and configuration information, and contact Huawei technical support personnel.
7. End.