PTP/4/hwPtpPassiveMeasureOverflow_clear

Message

PTP/4/hwPtpPassiveMeasureOverflow_clear: The time offset of the passive port is normal. (hwPtpPortName=[hwPtpPortName], hwPtpPortIfIndex=[hwPtpPortIfIndex], hwPtpPortRingFiberLengthChangeValue=[hwPtpPortRingFiberLengthChangeValue], hwPtpPortRingFiberLengthChangeValueFlag=[hwPtpPortRingFiberLengthChangeValueFlag], hwPtpPassiveAlarmThreshold=[hwPtpPassiveAlarmThreshold])

In VS mode, this log is supported only by the admin VS.

Parameters

Parameter Name Parameter Meaning

hwPtpPortName

Name of the current port.

hwPtpPortIfIndex

Index of the current port.

hwPtpPortRingFiberLengthChangeValue

New time offset caused by the fiber length change of the current port. (unit: ns)

hwPtpPortRingFiberLengthChangeValueFlag

Plus or minus sign of the new time offset caused by the fiber change of the current port.

The value can be:

Minus sign (0).

Positive sign (1).

hwPtpPassiveAlarmThreshold

Passive monitoring threshold configured on the current device.

Possible Causes

A new asymmetric correction value was set on the port where the passive measure overflow alarm was generated.

Procedure

This log message is informational only, and no action is required.