PTP/3/hwPtpStandardTimeOffsetOver_active: The ptp standard time offset is abnormal. (hwPtpStandardTimeOffset=[hwPtpStandardTimeOffset], hwPtpAlarmThresholdStandardTimeOffset=[hwPtpAlarmThresholdStandardTimeOffset])
In VS mode, this log is supported only by the admin VS.
Parameter Name | Parameter Meaning |
---|---|
hwPtpStandardTimeOffset |
The standard time offset. |
hwPtpAlarmThresholdStandardTimeOffset |
Threshold of the standard time offset. |
The deviation between the external baseline reference time and PTP time is out of the specified value range.
1. Adjust the time of the current PTP time source to be the same as the external baseline time, and check whether the alarm is cleared.
2. Collect alarm, log, and configuration information, and contact Huawei technical support personnel.
3. End.