SFLOW/4/hwSFlowUnsupportedBoard_active

Message

SFLOW/4/hwSFlowUnsupportedBoard_active: The board doesn't support sFlow. (Slot=[hwSFlowEnSlot])

This log is supported only on NetEngine 8000 F1A.

In VS mode, this log is supported only by the admin VS.

Description

The board does not support sFlow.

Parameters

Parameter Name Parameter Meaning

hwSFlowEnSlot

Slot ID.

Possible Causes

sFlow is enabled in the slot view of the board that does not support sFlow.

Procedure

1. Check whether the card supports sFlow based on the slot ID in the alarm information.

2. Replace the card with one that supports sFlow or delete the sFlow configuration in the slot view. Check whether the alarm is cleared.

  • If the alarm is cleared, go to Step 4.
  • If the alarm persists, go to Step 3.

3. Collect trap, log, and configuration information, and contact technical support personnel.

4. The procedure ends.