SYSTEM/2/hwSystemConfigError_clear-144129

Message

SYSTEM/2/hwSystemConfigError_clear: The system configuration error has been rectified. ( EntityTrapFaultID = [EntityTrapFaultID])

In VS mode, this log is supported only by the admin VS.

Parameters

Parameter Name Parameter Meaning

EntityTrapFaultID

Trap error code:

  • 144128: The PAF version is inconsistent with the version of the startup software package.
  • 144129: The boards and subcards of the device are not inserted into the corresponding slots.
  • 144130: The versions of the active and standby main control boards are inconsistent.
  • 144133: The memory of the active main control board is inconsistent with that of the standby main control board.
  • 144134: The PTN startup mode does not match the mode selected during license activation.

Possible Causes

The fault was rectified when the boards and subcards were installed in incorrect slots.

Procedure

This alarm message is informational only, and no action is required.