DEVM/1/hwVoltFallingAlarm_active: Voltage exceeded the lower prealarm limit. (BaseTrapSeverity=[BaseTrapSeverity], BaseTrapProbableCause=[BaseTrapProbableCause], BaseTrapEventType=[BaseTrapEventType], EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalName=[EntPhysicalName], BaseThresholdValue=[BaseThresholdValue], BaseThresholdUnit=[BaseThresholdUnit], LowCritical=[BaseThresholdLowCritical], LowWarning=[BaseThresholdLowWarning])
In VS mode, this log is supported only by the admin VS.
Parameter Name | Parameter Meaning |
---|---|
BaseTrapSeverity |
Indicates the level of trap. |
BaseTrapProbableCause |
Indicates the possible cause of trap. |
BaseTrapEventType |
Indicates the type of trap. |
EntityPhysicalIndex |
Indicates the physical index. |
EntPhysicalName |
Indicates the textual name of the physical entity. |
BaseThresholdValue |
Indicates the actual value. |
BaseThresholdUnit |
Indicates the unit of the value (mV). |
BaseThresholdLowCritical |
Indicates the upper critical limit. |
BaseThresholdLowWarning |
Indicates the minor upper limit. |
Cause 1: The PDF power supply was insufficient.
Cause 2: The power supply module was faulty.
Cause 1: The PDF power supply was insufficient.
Cause 2: The power supply module was faulty.
1.Run the display voltage slot slot-id command in the user view to view the voltage of each board.
2.Check whether the PDF power supply is sufficient.
3.Increase the PDF power supply and check whether the trap is cleared.
4. Replace the board and check whether the trap is cleared.
5. Collect the trap information, log information, and configuration of the router, and contact technical support personnel.
6. End.