EOAM-Y1731/4/hwY1731LckDefect_active

Message

EOAM-Y1731/4/hwY1731LckDefect_active: MEP enters LCK defect condition. (MdIndex=[MdIndex], MaIndex=[MaIndex], MdName=[MdName], MaName=[MaName], MepId=[MepId])

Description

A MEP enterd the LCK faulty state.

Parameters

Parameter Name Parameter Meaning

MdName

Name of an MD

MaName

Name of an MA

MepId

MEP ID

MdIndex

Index of an MD

MaIndex

Index of an MA

Possible Causes

The MEP received an LCK packet sent by a MEP in the inner layer MA.

Procedure

1. Check whether the mep mep-id mep-id lck enable level level-value command is run on a MEP in an inner MA. If this command is run, check whether the specified level is the same as the level of the MD to which the MEP generating the alarm belongs.

  • If the levels match, go to 2.
  • If the levels do not match, go to 3.

2. Run the undo mep mep-id mep-id lck enable command to disable the Ethernet lock (ETH-LCK) function on the MEP.

3. Collect alarm information and configuration information, and then contact technical support personnel.

4. End.