hwClockAttributeTable

The clock Attribute table.

The clock source attribute table.

The index of the table is hwClockAttributeChassisIndex.

OID

Object

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.5.25.186.1.9.1.1

hwClockAttributeChassisIndex

Integer32{(1,2147483647)}

not-accessible

The chassis index.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.186.1.9.1.2

hwClockAttributeSysClkRunMode

INTEGER{normal(0),freeRun(1),hold(2)}

read-write

The run mode of system clock.

The actually supported access is read-only.

1.3.6.1.4.1.2011.5.25.186.1.9.1.3

hwClockAttributeSsmControl

INTEGER{on(0),off(1)}

read-write

The flag whether SSM is concerned with the clock source selection.

The actually supported access is read-only.

1.3.6.1.4.1.2011.5.25.186.1.9.1.4

hwClockAttributeFreqCheckEnable

INTEGER{enabled(1),disabled(2)}

read-write

The enable flag of frequency check.

The actually supported access is read-only.

1.3.6.1.4.1.2011.5.25.186.1.9.1.5

hwClockAttributeRetrieveMode

INTEGER{retrieve(0),noRetrieve(1)}

read-write

The retrieve mode of system clock.

The actually supported access is read-only.

1.3.6.1.4.1.2011.5.25.186.1.9.1.6

hwClockAttributeWtrTime

Integer32{(0,12)}

read-write

The time waiting for retrieve.

The actually supported access is read-only.

1.3.6.1.4.1.2011.5.25.186.1.9.1.7

hwClockAttributeHoldOffTime

Integer32{(300,1800)}

read-write

The holdoff-time when the system source is lost.

The actually supported access is read-only.

1.3.6.1.4.1.2011.5.25.186.1.9.1.8

hwClockAttributeOutThreshold

INTEGER{prc(2),ssua(4),ssub(8),sec(11),dnu(15)}

read-write

The Threshold of out put.

The actually supported access is read-only.

1.3.6.1.4.1.2011.5.25.186.1.9.1.9

hwClockAttributeSysMaxOutSsm

INTEGER{unk(0),prc(2),ssua(4),ssub(8),sec(11),prtc(8194),eprtc(8450),esec(8715),eprc(8962)}

read-write

The max ssm of system out put.

The actually supported access is read-only.

1.3.6.1.4.1.2011.5.25.186.1.9.1.10

hwClockAttribute2M1MaxOutSsm

INTEGER{unk(0),prc(2),ssua(4),ssub(8),sec(11)}

read-write

The max ssm of 2msync-1 out put.

The actually supported access is read-only.

1.3.6.1.4.1.2011.5.25.186.1.9.1.11

hwClockAttribute2M2MaxOutSsm

INTEGER{unk(0),prc(2),ssua(4),ssub(8),sec(11)}

read-write

The max ssm of 2msync-2 out put.

The actually supported access is read-only.

1.3.6.1.4.1.2011.5.25.186.1.9.1.12

hwClockAttributeSysClkLockMode

INTEGER{freeRun(0),fastLock(1),lock(2),hold(3),freeRunJudge(16),holdJudge(19)}

read-only

The Lock mode of system clock.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.186.1.9.1.13

hwClockAttributeExtendSsmControl

INTEGER{on(0),off(1)}

read-write

The flag whether Extend SSM is concerned with the clock source selection.

The actually supported access is read-only.

1.3.6.1.4.1.2011.5.25.186.1.9.1.14

hwClockAttributeInternalClockId

Integer32{(0,15)}

read-write

The internal clockid of the device.

The actually supported access is read-only.

1.3.6.1.4.1.2011.5.25.186.1.9.1.15

hwClockAttributeTodProtocol

INTEGER{nmea(1),ubx(2),none(3),ccsa(4),ccsaopt2(5),g8271(6)}

read-write

1pps bits tod protocol.

The actually supported access is read-only.

Creation Restriction

No entry can be created in this table.

Modification Restriction

The entries in this table cannot be modified.

Deletion Restriction

The entries in this table cannot be deleted.

Access Restriction

The entries in this table can be read without restriction.
Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.