This table describes Huawei device voltage objects.
The indexes of the table are hwEntityVolSlot, hwEntityVolI2CId, hwEntityVolAddr, hwEntityVolChannel.
OID |
Object |
Syntax |
Max Access |
Description |
Implemented Specifications |
---|---|---|---|---|---|
1.3.6.1.4.1.2011.5.25.31.1.1.9.1.1 |
hwEntityVolSlot |
Integer32 |
read-only |
This object indicates the slot ID of an entity. |
For example, if 18022399 is displayed for a router, it needs to be first converted into hexadecimal value 0x112FFFF. The first 1 indicates the chassis number, and the two digits following the chassis number indicate a hexadecimal slot ID. The hexadecimal slot ID is then converted into a decimal number, that is, 18. The last four Fs can be ignored. Therefore, value 18022399 indicates slot 18 of chassis 1. |
1.3.6.1.4.1.2011.5.25.31.1.1.9.1.2 |
hwEntityVolI2CId |
Integer32 |
read-only |
This object indicates the I2C of the entity voltage. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.31.1.1.9.1.3 |
hwEntityVolAddr |
Integer32 |
read-only |
This object indicates the address of the entity voltage. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.31.1.1.9.1.4 |
hwEntityVolChannel |
Integer32 |
read-only |
This object indicates the channel of the entity voltage. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.31.1.1.9.1.5 |
hwEntityVolStatus |
INTEGER{abnormal(0),normal(1),major(2),fatal(3)} |
read-only |
This object indicates the status of the entity voltage. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.31.1.1.9.1.6 |
hwEntityVolRequired |
Integer32 |
read-only |
This object indicates the required value of the entity voltage. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.31.1.1.9.1.7 |
hwEntityVolCurValue |
Integer32 |
read-only |
This object indicates the current value of the entity voltage. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.31.1.1.9.1.8 |
hwEntityVolRatio |
Integer32 |
read-only |
This object indicates the voltage split ratio of the entity voltage. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.31.1.1.9.1.9 |
hwEntityVolLowAlmMajor |
Integer32 |
read-write |
This object indicates the entity low-voltage alarm threshold. |
The actually supported access is read-write. |
1.3.6.1.4.1.2011.5.25.31.1.1.9.1.10 |
hwEntityVolLowAlmFatal |
Integer32 |
read-write |
This object indicates the entity low-voltage fatal alarm threshold. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.31.1.1.9.1.11 |
hwEntityVolHighAlmMajor |
Integer32 |
read-write |
This object indicates the entity high-voltage alarm threshold. |
The actually supported access is read-write. |
1.3.6.1.4.1.2011.5.25.31.1.1.9.1.12 |
hwEntityVolHighAlmFatal |
Integer32 |
read-write |
This object indicates the entity high-voltage fatal alarm threshold. |