hwVoltageInfoTable

This table describes Huawei device voltage objects.

The indexes of the table are hwEntityVolSlot, hwEntityVolI2CId, hwEntityVolAddr, hwEntityVolChannel.

OID

Object

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.5.25.31.1.1.9.1.1

hwEntityVolSlot

Integer32

read-only

This object indicates the slot ID of an entity.

For example, if 18022399 is displayed for a router, it needs to be first converted into hexadecimal value 0x112FFFF. The first 1 indicates the chassis number, and the two digits following the chassis number indicate a hexadecimal slot ID. The hexadecimal slot ID is then converted into a decimal number, that is, 18. The last four Fs can be ignored. Therefore, value 18022399 indicates slot 18 of chassis 1.

1.3.6.1.4.1.2011.5.25.31.1.1.9.1.2

hwEntityVolI2CId

Integer32

read-only

This object indicates the I2C of the entity voltage.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.31.1.1.9.1.3

hwEntityVolAddr

Integer32

read-only

This object indicates the address of the entity voltage.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.31.1.1.9.1.4

hwEntityVolChannel

Integer32

read-only

This object indicates the channel of the entity voltage.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.31.1.1.9.1.5

hwEntityVolStatus

INTEGER{abnormal(0),normal(1),major(2),fatal(3)}

read-only

This object indicates the status of the entity voltage.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.31.1.1.9.1.6

hwEntityVolRequired

Integer32

read-only

This object indicates the required value of the entity voltage.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.31.1.1.9.1.7

hwEntityVolCurValue

Integer32

read-only

This object indicates the current value of the entity voltage.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.31.1.1.9.1.8

hwEntityVolRatio

Integer32

read-only

This object indicates the voltage split ratio of the entity voltage.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.31.1.1.9.1.9

hwEntityVolLowAlmMajor

Integer32

read-write

This object indicates the entity low-voltage alarm threshold.

The actually supported access is read-write.

1.3.6.1.4.1.2011.5.25.31.1.1.9.1.10

hwEntityVolLowAlmFatal

Integer32

read-write

This object indicates the entity low-voltage fatal alarm threshold.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.31.1.1.9.1.11

hwEntityVolHighAlmMajor

Integer32

read-write

This object indicates the entity high-voltage alarm threshold.

The actually supported access is read-write.

1.3.6.1.4.1.2011.5.25.31.1.1.9.1.12

hwEntityVolHighAlmFatal

Integer32

read-write

This object indicates the entity high-voltage fatal alarm threshold.

This object is implemented as defined in the corresponding MIB files.

Creation Restriction

The entries in this table cannot be created.

Modification Restriction

The entries in this table cannot be modified.

Deletion Restriction

The entries in this table cannot be deleted.

Access Restriction

The entries in this table can be read without restriction.
Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.