This table describes Huawei device voltage objects.
The indexes of the table are hwEntityVolSlot, hwEntityVolI2CId, hwEntityVolAddr, hwEntityVolChannel.
| OID | Object | Syntax | Max Access | Description | Implemented Specifications | 
|---|---|---|---|---|---|
| 1.3.6.1.4.1.2011.5.25.31.1.1.9.1.1 | hwEntityVolSlot | Integer32 | read-only | This object indicates the slot ID of an entity. | For example, if 18022399 is displayed for a router, it needs to be first converted into hexadecimal value 0x112FFFF. The first 1 indicates the chassis number, and the two digits following the chassis number indicate a hexadecimal slot ID. The hexadecimal slot ID is then converted into a decimal number, that is, 18. The last four Fs can be ignored. Therefore, value 18022399 indicates slot 18 of chassis 1. | 
| 1.3.6.1.4.1.2011.5.25.31.1.1.9.1.2 | hwEntityVolI2CId | Integer32 | read-only | This object indicates the I2C of the entity voltage. | This object is implemented as defined in the corresponding MIB files. | 
| 1.3.6.1.4.1.2011.5.25.31.1.1.9.1.3 | hwEntityVolAddr | Integer32 | read-only | This object indicates the address of the entity voltage. | This object is implemented as defined in the corresponding MIB files. | 
| 1.3.6.1.4.1.2011.5.25.31.1.1.9.1.4 | hwEntityVolChannel | Integer32 | read-only | This object indicates the channel of the entity voltage. | This object is implemented as defined in the corresponding MIB files. | 
| 1.3.6.1.4.1.2011.5.25.31.1.1.9.1.5 | hwEntityVolStatus | INTEGER{abnormal(0),normal(1),major(2),fatal(3)} | read-only | This object indicates the status of the entity voltage. | This object is implemented as defined in the corresponding MIB files. | 
| 1.3.6.1.4.1.2011.5.25.31.1.1.9.1.6 | hwEntityVolRequired | Integer32 | read-only | This object indicates the required value of the entity voltage. | This object is implemented as defined in the corresponding MIB files. | 
| 1.3.6.1.4.1.2011.5.25.31.1.1.9.1.7 | hwEntityVolCurValue | Integer32 | read-only | This object indicates the current value of the entity voltage. | This object is implemented as defined in the corresponding MIB files. | 
| 1.3.6.1.4.1.2011.5.25.31.1.1.9.1.8 | hwEntityVolRatio | Integer32 | read-only | This object indicates the voltage split ratio of the entity voltage. | This object is implemented as defined in the corresponding MIB files. | 
| 1.3.6.1.4.1.2011.5.25.31.1.1.9.1.9 | hwEntityVolLowAlmMajor | Integer32 | read-write | This object indicates the entity low-voltage alarm threshold. | The actually supported access is read-write. | 
| 1.3.6.1.4.1.2011.5.25.31.1.1.9.1.10 | hwEntityVolLowAlmFatal | Integer32 | read-write | This object indicates the entity low-voltage fatal alarm threshold. | This object is implemented as defined in the corresponding MIB files. | 
| 1.3.6.1.4.1.2011.5.25.31.1.1.9.1.11 | hwEntityVolHighAlmMajor | Integer32 | read-write | This object indicates the entity high-voltage alarm threshold. | The actually supported access is read-write. | 
| 1.3.6.1.4.1.2011.5.25.31.1.1.9.1.12 | hwEntityVolHighAlmFatal | Integer32 | read-write | This object indicates the entity high-voltage fatal alarm threshold. | This object is implemented as defined in the corresponding MIB files. |