hwPortAlarmDownEnableTable

This table describes association between interface alarms and the interface status.

Meaning: This table describes the alarm status of the port.

The index of the table is hwPhysicalPortDownIfIndex.

OID

Object

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.5.25.157.1.15.1.1.1

hwPhysicalPortDownIfIndex

INTEGER

not-accessible

This object indicates the interface index.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.157.1.15.1.1.2

hwPhysicalPortDownName

OCTET STRING{(0,64)}

read-only

This object indicates the name of a physical interface.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.157.1.15.1.1.3

hwPhysicalPortCrcEnabledDown

INTEGER{disable(0),enable(1)}

read-write

This object indicates association between the CRC error alarm and the interface status. If a CRC error alarm is generated, the involved interface goes Down accordingly. The default value is disable(0).

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.157.1.15.1.1.4

hwPhysicalPortSymbolEnabledDown

INTEGER{disable(0),enable(1)}

read-write

This object indicates association between the Symbol error alarm and the interface status. If a Symbol error alarm is generated, the involved interface goes Down accordingly. The default value is disable(0).

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.157.1.15.1.1.5

hwPhysicalPortInputEnabledDown

INTEGER{disable(0),enable(1)}

read-write

This object indicates association between the Input error alarm and the interface status. If an Input error alarm is generated, the involved interface goes Down accordingly. The default value is disable(0).

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.157.1.15.1.1.6

hwPhysicalPortOutputEnabledDown

INTEGER{disable(0),enable(1)}

read-write

This object indicates association between the Output error alarm and the interface status. If an Output error alarm is generated, the involved interface goes Down accordingly. The default value is disable(0).

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.157.1.15.1.1.7

hwPhysicalPortSdhEnabledDown

INTEGER{disable(0),enable(1)}

read-write

This object indicates association between the SDH error alarm and the interface status. If an SDH error alarm is generated, the involved interface goes Down accordingly. The default value is disable(0).

NOTE:

This node is supported only on the NetEngine 8000 F1A.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.157.1.15.1.1.8

hwPhysicalPortBip8SdEnabledDown

INTEGER{disable(0),enable(1)}

read-write

Enalbe or disable the BIP8-SD error alarm result in physics down, and the default value is disable.

This object is implemented as defined in the corresponding MIB files.

Creation Restriction

Creation is not supported.

Modification Restriction

The entries in this table can be modified.

Deletion Restriction

This parameter cannot be deleted.

Access Restriction

The entries in this table can be accessed.