1.3.6.1.4.1.2011.5.25.333.1.1.11.1.1

hwTwampTwoWayDelayValue

Integer32{(0,1000)}

accessible-for-notify

The value of this object identifies the dual-ended delay.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.333.1.1.11.1.2

hwTwampTwoWayDelayValueUpperLimitThreshold

Integer32{(2,1000)}

read-create

This object indicates the upper limit(ms) of the two-way ETH-DM.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.333.1.1.11.1.3

hwTwampTwoWayDelayValueLowerLimitThreshold

Integer32{(1,999)}

read-create

This object indicates the lower limit(ms) of the two-way ETH-DM.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.333.1.1.11.1.99

hwTwampTwoWayDelayAlarmRowStatus

INTEGER{active(1),notInService(2),notReady(3),createAndGo(4),createAndWait(5),destroy(6)}

read-create

This object indicates the row status of this entry.

This object is implemented as defined in the corresponding MIB files.

Creation Restriction

You can create entries in this table.

Modification Restriction

The entries in this table can be modified.

Deletion Restriction

The entries in this table can be deleted.

Access Restriction

The entries in this table can be read without restriction.