isisNotificationTable

Objects seen in the most recent notification this instance of the IS-IS protocol.

The index of the table is isisSysInstance.

OID

Object

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.3.37.1.10.1.1.1

isisPduLspId

OCTET STRING{(0,0),(8,8)}

accessible-for-notify

An Octet String that uniquely identifies a Link State PDU.

This object is used only as the VB bound variable of the alarm.

1.3.6.1.3.37.1.10.1.1.2

isisPduFragment

OCTET STRING{(0,64)}

accessible-for-notify

Holds up to the first 64 bytes of a PDU that triggered the notification.

This object is used only as the VB bound variable of the alarm.

1.3.6.1.3.37.1.10.1.1.3

isisPduFieldLen

Unsigned32{(0,255)}

accessible-for-notify

Holds the System ID length reported in PDU we received.

This object is used only as the VB bound variable of the alarm.

1.3.6.1.3.37.1.10.1.1.4

isisPduMaxAreaAddress

Unsigned32{(0,255)}

accessible-for-notify

Holds the Max Area Addresses reported in a PDU we received.

This object is used only as the VB bound variable of the alarm.

1.3.6.1.3.37.1.10.1.1.5

isisPduProtocolVersion

Unsigned32{(0,255)}

accessible-for-notify

Holds the Protocol version reported in PDU we received.

This object is used only as the VB bound variable of the alarm.

1.3.6.1.3.37.1.10.1.1.6

isisPduLspSize

Integer32{(0,2147483647)}

accessible-for-notify

Holds the size of LSP we received that is too big to forward.

This object is used only as the VB bound variable of the alarm.

1.3.6.1.3.37.1.10.1.1.7

isisPduOriginatingBufferSize

Unsigned32{(0,16000)}

accessible-for-notify

Holds the size of isisSysOrigLSPBuffSize advertised by peer in TLV.

This object is used only as the VB bound variable of the alarm.

1.3.6.1.3.37.1.10.1.1.8

isisPduProtocolsSupported

OCTET STRING{(0,255)}

accessible-for-notify

The list of protocols supported by an adjacent system. This may be empty.

This object is used only as the VB bound variable of the alarm.

1.3.6.1.3.37.1.10.1.1.9

isisAdjState

INTEGER{down(1),initializing(2),up(3),failed(4)}

accessible-for-notify

The current state of an adjacency.

This object is used only as the VB bound variable of the alarm.

1.3.6.1.3.37.1.10.1.1.10

isisPduRemoteRouterID

Unsigned32

accessible-for-notify

The Router ID of a remote system. If not known, we set this to 0.

This object is used only as the VB bound variable of the alarm.

Creation Restriction

The entries in this table cannot be created.

Modification Restriction

The entries in this table cannot be modified.

Deletion Restriction

The entries in this table cannot be deleted.

Access Restriction

The entries in this table cannot be read.
Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
< Previous topic