isisCircuitCounterTable

Circuit specific counters for one instance of the IS-IS protocol on the system.

The indexes of the table are isisSysInstance, isisCircIndex, isisCircuitType.

OID

Object

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.3.37.1.5.2.1.1

isisCircuitType

INTEGER{lanlevel1(1),lanlevel2(2),p2pcircuit(3)}

not-accessible

What type of circuit saw these counts?

The point to point Hello PDU includes

both L1 and L2, and ISs form a single

adjacency on point to point links.

Thus we combine counts on

point to point links into one group.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.3.37.1.5.2.1.2

isisCircAdjChanges

Counter32

read-only

The number of times an adjacency state change has

occurred on this circuit.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.3.37.1.5.2.1.3

isisCircNumAdj

Unsigned32

read-only

The number of adjacencies on this circuit.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.3.37.1.5.2.1.4

isisCircInitFails

Counter32

read-only

The number of times initialization of this circuit has

failed.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.3.37.1.5.2.1.5

isisCircRejAdjs

Counter32

read-only

The number of times an adjacency has been rejected on

this circuit.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.3.37.1.5.2.1.6

isisCircIDFieldLenMismatches

Counter32

read-only

The number of times an IS-IS control PDU with an ID

field length different to that for this system has been

received.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.3.37.1.5.2.1.7

isisCircMaxAreaAddrMismatches

Counter32

read-only

The number of times an IS-IS control PDU with a

max area address field different to that for this

system has been received.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.3.37.1.5.2.1.8

isisCircAuthTypeFails

Counter32

read-only

The number of times an IS-IS control PDU with

an auth type field different to that for this

system has been received.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.3.37.1.5.2.1.9

isisCircAuthFails

Counter32

read-only

The number of times an IS-IS control PDU with

the correct auth type has failed to pass authentication

validation.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.3.37.1.5.2.1.10

isisCircLANDesISChanges

Counter32

read-only

The number of times the Designated IS has changed

on this circuit at this level. If the circuit is

point to point, this count is zero.

This object is implemented as defined in the corresponding MIB files.

Creation Restriction

The entries in this table cannot be created.

Modification Restriction

The entries in this table cannot be modified.

Deletion Restriction

The entries in this table cannot be deleted.

Access Restriction

None.
Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
< Previous topic Next topic >