(Optional) Configuring the Class Attribute to Carry the CAR Value

You can configure the Class attribute to carry or not to carry the committed access rate (CAR) value to ensure the communication between the NetEngine 8000 F and RADIUS servers from different vendors.

Context

As specified in the standard RADIUS protocol, the Class attribute carried in an Access-Accept packet sent by a RADIUS server to a client must be returned to the accounting server without any change in an Accounting-Request packet.

The NetEngine 8000 F extends the standard RADIUS protocol by adding the CAR value to the Class attribute (RADIUS attribute 25).

Procedure

  1. Run system-view

    The system view is displayed.

  2. Run radius-server group group-name

    The RADIUS server group view is displayed.

  3. Run radius-server class-as-car [ enable-pir ]

    The Class attribute is configured to carry the CAR value.

    To meet the requirements of various RADIUS servers, the NetEngine 8000 F can use the Class attribute (RADIUS attribute 25) or Vendor-Specific attribute (RADIUS attribute 26) to send the CAR value to the RADIUS server. The preceding commands configure how to use the RADIUS attribute 25 to send the CAR value to the RADIUS server.

  4. Run commit

    The configuration is committed.