Enabling Self-healing of an Atom GNSS Module

This section describes how to enable self-healing of an Atom GNSS module in response to an IIC watchdog abnormality.

Context

After self-healing is enabled on an Atom GNSS module, the Atom GNSS module is automatically reset, and the SyncE and 1588v2 functions are disabled from the involved interface. After the WTR timer is expired, the SyncE and 1588v2 functions are re-enabled, and services are restored. If self-healing is not enabled, the involved device remains abnormal and waits for user processing.

Perform the following operations on the router where the Atom GNSS module houses:

Procedure

  1. Run system-view

    The system view is displayed.

  2. Run interface interface-type interface-number

    The interface view is displayed.

  3. Run smart-clock recovery enable

    Self-healing is enabled on the Atom GNSS module.

  4. Run commit

    The configuration is committed.

Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
< Previous topic