After multiple T-BCs are configured with the input of BITS signals, clock source attributes for BMC selection can be configured on the T-BCs to allow the T-BCs to participate in BMC selection. The local clocks of T-BCs can also be configured to participate in BMC selection. BMCA can be used to dynamically determine the T-GM. The T-GM provides time signals for the entire CU-106 network. T-BCs use CU-106 to obtain time synchronization information from the T-GM.
Perform the following steps on each router that is connected to a BITS source on the CU-106 network:
The system view is displayed.
The grandmaster clock ID is specified for the BITS source.
The accuracy value of the clock source is set.
In T-BC mode, the default accuracy value (0xFE) of the local clock source is used.
The clock class is set for the BITS source.
In T-BC mode, the default clock class is 248. If the clock class of a locked clock is less than 135, the clock class automatically changes to 165 after the clock is out of lock and this clock class cannot be configured.
Priority2 of the local clock source is set.
The priority of the local clock source is set.
The time source of the local clock source is configured.
The configuration is committed.