Configuring the Alarm Function for Pause-Frame Errors Received on an Interface

This section describes how to configure the alarm function for pause-frame errors received on an interface.

Context

A device generates an alarm and sends it to an NMS only when the number of pause-frame error packets sent or received by the device reaches the upper threshold for three consecutive detection intervals. The device sends a clear alarm to the NMS only when the number of pause-frame error packets sent or received by the device falls below the lower threshold for three consecutive detection intervals.

Procedure

  1. Run system-view

    The system view is displayed.

  2. Run interface interface-type interface-number

    The view of an interface is displayed.

  3. Run trap-threshold pause-frame high-threshold high-threshold low-threshold low-threshold interval-second interval

    The upper threshold, lower threshold, and detection interval for the pause-frame error alarm are set.

  4. Run commit

    The configuration is committed.

Copyright © Huawei Technologies Co., Ltd.