This section describes how to configure time attributes for SMPTE-2059-2 packets. SMPTE-2059-2 nodes exchange Announce, Sync, and Delay or Pdelay packets to send time information and maintain SMPTE-2059-2 connections. You can set the interval at which an SMPTE-2059-2 interface sends Announce, Sync, and Delay or Pdelay packets and the maximum number of Announce packet timeouts. Using the default time attribute values is recommended.
During SMPTE-2059-2 clock synchronization, an Announce packet is sent to determine the master-slave hierarchy, where the upstream node that advertises the synchronization time is the master device and the downstream node that receives the synchronization time is called the slave device. The master device sends Sync packets to the slave device to transmit performance parameters of time signals. In addition, the delay measurement mechanism can be implemented to ensure the accuracy of time signals.
If the packet sending interval is too small, devices frequently exchange SMPTE-2059-2 packets, consuming too many bandwidth resources. If the packet sending interval is too large, the precision of time synchronization cannot be guaranteed. Given that the time precision is guaranteed, set the packet sending interval to a large value.
Perform the following operations on an SMPTE-2059-2 device: