This section describes the usage scenario, pre-configuration tasks, and configuration procedure for transmission alarm suppression. If a transmission alarm suppression threshold is configured, an alarm is reported only when the threshold is reached.
In the scenario where a router is connected to a transmission device, if the network is unstable, a large number of burr alarms may be generated. As a result, the physical status of interfaces will frequently change between up and down. To prevent these alarms from frequently flapping or configure the device to ignore these burr alarms, you need to enable transmission alarm suppression.
Before configuring transmission alarm suppression, complete the following tasks:
Transmission alarm suppression takes effect on an interface only after transmission alarm customization is configured on the interface.
The system view is displayed.
Transmission alarm suppression is enabled, and suppression parameters are set.
The configuration is committed.
After configuring transmission alarm suppression, verify the configuration.
Run the display transmission-alarm configuration command to check the transmission alarm configuration on an interface.