Configuration Precautions for Performance Management

Feature Requirements

Table 1 Feature requirements

Feature Requirements

Series

Models

Non-Admin VSs share system memory resources with each other. Memory resources cannot be separately allocated to the VSs.

NetEngine 8000 F

NetEngine 8000 F2A/NetEngine 8000 F1A

IP FPM measurement flags cannot be configured for VSs except Admin-VS.

NetEngine 8000 F

NetEngine 8000 F2A/NetEngine 8000 F1A

After a device is upgraded from the unified VS mode to the independent VS mode with existing configurations, data in all VSs except Admin-VS is lost. Before the upgrade, save the configuration file of a non-Admin-VS VS. After the upgrade, save the configuration file to the non-Admin VS directory for configuration restoration.

NetEngine 8000 F

NetEngine 8000 F2A/NetEngine 8000 F1A

DCN can be enabled only in Admin-VS.

NetEngine 8000 F

NetEngine 8000 F2A/NetEngine 8000 F1A

VSs except Admin-VS do not support independent NTP.

NetEngine 8000 F

NetEngine 8000 F2A/NetEngine 8000 F1A

Configurations cannot be concurrently committed for Admin-VS and non-Admin-VS VSs.

Configurations can be concurrently committed for multiple non-Admin-VS VSs. However, if configurations that affect Admin-VS are modified for a non-Admin VS, configurations cannot be committed for other non-Admin-VS VSs during configuration commission for this non-Admin-VS VS, and you need to try again in this case.

NetEngine 8000 F

NetEngine 8000 F2A/NetEngine 8000 F1A

The system determines VS specifications based on the memory of the master main control board.

1, If the memory of the master main control board is less than 8 GB, creating multiple VSs is not supported.

2, If the memory of the master main control board is greater than or equal to 8 GB but less than 16 GB, the system supports a maximum of four VSs.

3, If the memory of the master main control board is greater than or equal to 16 GB, the system supports a maximum of eight VSs.

Please plan VS resources properly.

NetEngine 8000 F

NetEngine 8000 F2A/NetEngine 8000 F1A

A device allows a maximum of 21 users to deliver configurations. Other users can only perform the query operation. The users in non-Admin VSs are in preemption mode.

NetEngine 8000 F

NetEngine 8000 F2A/NetEngine 8000 F1A

The maintenance assistant function does not apply to non-Admin VSs. Admin-VS collects information uniformly.

NetEngine 8000 F

NetEngine 8000 F2A/NetEngine 8000 F1A

Patch operations cannot be performed if the system CPU usage exceeds 70%, otherwise the patch operation will fail.

Perform patch operations after the system CPU usage falls below 70%.

NetEngine 8000 F

NetEngine 8000 F2A/NetEngine 8000 F1A

No patch can be installed if the sum of the existing memory usage and the memory usage predicted for patch installation exceeds 90%. Patch installation fails.

Install a patch after the system memory usage decreases.

NetEngine 8000 F

NetEngine 8000 F2A/NetEngine 8000 F1A

All VSs except Admin-VS do not support .dat configuration files, do not support fast startup in DAT mode.

NetEngine 8000 F

NetEngine 8000 F2A/NetEngine 8000 F1A

KPI files generated through the KPI diagnosis function are not independently saved by VS.

NetEngine 8000 F

NetEngine 8000 F2A/NetEngine 8000 F1A

GRESM labels in the system are unique and cannot conflict with each other even in different VSs. Do not configure the same GRESM label for different non-Admin VSs.

NetEngine 8000 F

NetEngine 8000 F2A/NetEngine 8000 F1A

The group-mac of L2PT and BPDU tunnels can be configured only in Admin-VS.

NetEngine 8000 F

NetEngine 8000 F2A/NetEngine 8000 F1A

Different VSs cannot be configured with the same PWE3 static VC label.

NetEngine 8000 F

NetEngine 8000 F2A/NetEngine 8000 F1A

The sampling mode and destination address are configured in the Slot view and can only be configured in Admin-VS.

NetEngine 8000 F

NetEngine 8000 F2A/NetEngine 8000 F1A

The BFD local descriptor (MD) is unique on a device. Different VSs cannot be configured with the same local descriptor.

NetEngine 8000 F

NetEngine 8000 F2A/NetEngine 8000 F1A

The EVPN supports multiple VSs, but the ESI-ID is unique on a device. Do not configure the same ESI-ID for different non-Admin VSs.

NetEngine 8000 F

NetEngine 8000 F2A/NetEngine 8000 F1A