Feature Requirements |
Series |
Models |
---|---|---|
Non-Admin VSs share system memory resources with each other. Memory resources cannot be separately allocated to the VSs. |
NetEngine 8000 F |
NetEngine 8000 F2A/NetEngine 8000 F1A |
IP FPM measurement flags cannot be configured for VSs except Admin-VS. |
NetEngine 8000 F |
NetEngine 8000 F2A/NetEngine 8000 F1A |
After a device is upgraded from the unified VS mode to the independent VS mode with existing configurations, data in all VSs except Admin-VS is lost. Before the upgrade, save the configuration file of a non-Admin-VS VS. After the upgrade, save the configuration file to the non-Admin VS directory for configuration restoration. |
NetEngine 8000 F |
NetEngine 8000 F2A/NetEngine 8000 F1A |
DCN can be enabled only in Admin-VS. |
NetEngine 8000 F |
NetEngine 8000 F2A/NetEngine 8000 F1A |
VSs except Admin-VS do not support independent NTP. |
NetEngine 8000 F |
NetEngine 8000 F2A/NetEngine 8000 F1A |
Configurations cannot be concurrently committed for Admin-VS and non-Admin-VS VSs. Configurations can be concurrently committed for multiple non-Admin-VS VSs. However, if configurations that affect Admin-VS are modified for a non-Admin VS, configurations cannot be committed for other non-Admin-VS VSs during configuration commission for this non-Admin-VS VS, and you need to try again in this case. |
NetEngine 8000 F |
NetEngine 8000 F2A/NetEngine 8000 F1A |
The system determines VS specifications based on the memory of the master main control board. 1, If the memory of the master main control board is less than 8 GB, creating multiple VSs is not supported. 2, If the memory of the master main control board is greater than or equal to 8 GB but less than 16 GB, the system supports a maximum of four VSs. 3, If the memory of the master main control board is greater than or equal to 16 GB, the system supports a maximum of eight VSs. Please plan VS resources properly. |
NetEngine 8000 F |
NetEngine 8000 F2A/NetEngine 8000 F1A |
A device allows a maximum of 21 users to deliver configurations. Other users can only perform the query operation. The users in non-Admin VSs are in preemption mode. |
NetEngine 8000 F |
NetEngine 8000 F2A/NetEngine 8000 F1A |
The maintenance assistant function does not apply to non-Admin VSs. Admin-VS collects information uniformly. |
NetEngine 8000 F |
NetEngine 8000 F2A/NetEngine 8000 F1A |
Patch operations cannot be performed if the system CPU usage exceeds 70%, otherwise the patch operation will fail. Perform patch operations after the system CPU usage falls below 70%. |
NetEngine 8000 F |
NetEngine 8000 F2A/NetEngine 8000 F1A |
No patch can be installed if the sum of the existing memory usage and the memory usage predicted for patch installation exceeds 90%. Patch installation fails. Install a patch after the system memory usage decreases. |
NetEngine 8000 F |
NetEngine 8000 F2A/NetEngine 8000 F1A |
All VSs except Admin-VS do not support .dat configuration files, do not support fast startup in DAT mode. |
NetEngine 8000 F |
NetEngine 8000 F2A/NetEngine 8000 F1A |
KPI files generated through the KPI diagnosis function are not independently saved by VS. |
NetEngine 8000 F |
NetEngine 8000 F2A/NetEngine 8000 F1A |
GRESM labels in the system are unique and cannot conflict with each other even in different VSs. Do not configure the same GRESM label for different non-Admin VSs. |
NetEngine 8000 F |
NetEngine 8000 F2A/NetEngine 8000 F1A |
The group-mac of L2PT and BPDU tunnels can be configured only in Admin-VS. |
NetEngine 8000 F |
NetEngine 8000 F2A/NetEngine 8000 F1A |
Different VSs cannot be configured with the same PWE3 static VC label. |
NetEngine 8000 F |
NetEngine 8000 F2A/NetEngine 8000 F1A |
The sampling mode and destination address are configured in the Slot view and can only be configured in Admin-VS. |
NetEngine 8000 F |
NetEngine 8000 F2A/NetEngine 8000 F1A |
The BFD local descriptor (MD) is unique on a device. Different VSs cannot be configured with the same local descriptor. |
NetEngine 8000 F |
NetEngine 8000 F2A/NetEngine 8000 F1A |
The EVPN supports multiple VSs, but the ESI-ID is unique on a device. Do not configure the same ESI-ID for different non-Admin VSs. |
NetEngine 8000 F |
NetEngine 8000 F2A/NetEngine 8000 F1A |