In VPLS networking, the clock frequencies between the two ends are synchronized and CFM is enabled to monitor link connectivity. If the unidirectional delay measurement needs to be performed for a link, one-way frame delay measurement can be configured to monitor the quality of the link.
To implement singular or periodic single-ended frame loss measurement for a PW, configure on-demand single-end frame loss measurement in VLL networking.
To implement continual single-ended frame loss measurement for a PW, configure proactive single-ended frame loss measurement in VLL networking.
Configure on-demand single-ended frame loss measurement for a PW.
Perform the following steps on the devices at both ends of a PW where single-ended frame loss measurement will be implemented:
The system view is displayed.
The MD view is displayed.
The MA view is displayed.
Run mapvsivsi-name
The MA is bound to a VSI.
Run mep mep-id
The MEP is configured.
Run remote-mep mep-idmep-id
The remote MEP ID is configured.
The CCM transmission function is enabled.
Run remote-mep ccm-receive [ mep-idmep-id ] enable
The CCM reception function is enabled.
Configure a test instance.
On the receiving device of a PW where single-ended frame loss measurement will be implemented, run test-idtest-id [ testid-file ]mepmep-id [ peer-ippeer-ip [ vc-idvc-id ] ] [ descriptiondescription ]
A test instance is configured on the device.
On the transmitting device on a PW where single-ended frame loss measurement will be implemented, run test-id test-id [ testid-file ] mep mep-id [ mac mac-address | remote-mep mep-id ] [ peer-ip peer-ip [ vc-id vc-id ] ] [ description description ]
A test instance is configured on the device.
On the receiving device of a PW where single-ended frame loss measurement will be implemented, run loss-measure single-ended receivetest-idtest-id-value
The LMM reception function is configured on the device.
On the transmitting device of a PW where single-ended frame loss measurement will be implemented, run loss-measure single-ended send test-id test-id-value interval { 1000 | 10000 } count count-value
On-demand single-ended frame loss measurement is configured for a PW.
Run commit
The configuration is committed.
Configure on-demand single-ended frame loss measurement for an AC.
Run system-view
The system view is displayed.
Run cfm md md-name
The MD view is displayed.
Run ma ma-name
The MA view is displayed.
Perform the following steps on the devices where the MEPs reside:
Run mep mep-id
The MEP is configured.
Run remote-mep mep-id mep-id
The remote MEP ID is configured.
The CCM transmission function is enabled.
Run remote-mep ccm-receive [ mep-id mep-id ] enable
The CCM reception function is enabled.
Configure a test instance.
On the receiving device of an AC where single-ended frame loss measurement will be implemented, run test-id test-id [ testid-file ] mep mep-id [ description description ]
A test instance is configured on the device.
On the transmitting device on an AC where single-ended frame loss measurement will be implemented, run test-id test-id [ testid-file ] mep mep-id [ mac mac-address | remote-mep mep-id ] [ description description ]
A test instance is configured on the device.
On the receiving device of an AC where single-ended frame loss measurement will be implemented, run loss-measure single-ended receivetest-id test-id-value
The LMM reception function is configured on the device.
Run commit
The configuration is committed.
On the transmitting device of an AC where single-ended frame loss measurement will be implemented, run loss-measure single-ended send test-id test-id-value interval { 1000 | 10000 } count count-value
On-demand single-ended frame loss measurement is configured for an AC.
Run commit
The configuration is committed.
Perform the following steps on the PEs at both ends of a PW where proactive single-ended frame loss measurement will be implemented:
Run system-view
The system view is displayed.
(Optional) Run y1731 pm-mode enable
Performance management (PM) to manage Y.1731 proactive performance statistics is enabled. PM saves the statistics to generated statistics files and then sends the files to the NMS.
Run cfm md md-name
The MD view is displayed.
Run ma ma-name
The MA view is displayed.
Run map vsi vsi-name
The MA is bound to a VSI.
Run mep mep-id
The MEP is configured.
Run remote-mep mep-id mep-id
The remote MEP ID is configured.
The CCM transmission function is enabled.
Run remote-mep ccm-receive [ mep-id mep-id ] enable
The CCM reception function is enabled.
Configure the test instance.
On the receiving device of a PW where single-ended frame loss measurement will be implemented:
Run test-id test-id [ testid-file ] mep mep-id [ mac mac-address | remote-mep mep-id ] [ peer-ip peer-ip [ vc-id vc-id ] | 8021p 8021p-value ] [ description description ]
A test instance is configured.
On the transmitting device of a PW where single-ended frame loss measurement will be implemented:
Run test-id test-id [ testid-file ] mep mep-id [ mac mac-address | remote-mep mep-id ] [ peer-ip peer-ip [ vc-id vc-id ] | 8021p 8021p-value ] [ description description ]
A test instance is configured.
Upper and lower thresholds are set for the near-end frame loss rate in proactive single-ended frame loss measurement based on a specified MEP.
Upper and lower thresholds are set for the near-end frame loss rate in proactive single-ended frame loss measurement based on a specified test instance.
Upper and lower thresholds are set for the far-end frame loss rate in proactive single-ended frame loss measurement based on a specified MEP.
Upper and lower thresholds are set for the far-end frame loss rate in proactive single-ended frame loss measurement based on a specified test instance.
On the receiving device on a PW where proactive single-ended frame loss measurement will be implemented, run loss-measure single-ended receive test-id test-id-value
The LMM reception function is configured on the device.
Run commit
The configuration is committed.
Proactive single-ended frame loss measurement is configured for a PW.
Run commit
The configuration is committed.
Run the display y1731 statistic-type single-loss [ test-id test-id-value ] [ count count-value ] command on the device that initiates single-ended frame loss measurement to check statistics about single-ended frame loss.