Configuring Dual-ended Frame Loss Measurement in BD EVPN Networking

In BD EVPN networking where CFM is enabled to monitor link connectivity, if accurate frame loss measurement needs to be performed for a link, configure dual-ended frame loss measurement to monitor the quality of the link.

Procedure

Dual-ended frame loss measurement in BD EVPN networking is carried out continuously to allow proactive reporting of frame loss or performance results.

Dual-ended frame loss measurement in BD EVPN networking is deployed on end-to-end MEPs. Frame loss statistics are collected based on the transmit and receive counters carried in CCMs. Dual-ended frame loss measurement can be successfully performed only when the RMEP is in the up state.

  1. Run system-view

    The system view is displayed.

  2. (Optional) Run y1731 pm-mode enable

    PM is enabled to manage and send Y.1731 proactive performance statistics to the NMS.

  3. Run cfm md md-name

    The MD view is displayed.

  4. Run ma ma-name

    The MA view is displayed.

  5. Perform the following steps on the devices where the MEP and RMEP reside:
    • On the CE, run map vlan vlan-id

      The MA is bound to a VLAN.

    • On the PE, run map bridge-domain bd-id

      The MA is bound to a specified BD instance.

  6. Run mep mep-id mep-id interface interface-type interface-number outward

    An MEP is configured.

  7. Run remote-mep mep-id mep-id

    An RMEP is configured.

  8. Run mep ccm-send enable

    The MEP is enabled to send CCMs.

  9. Run remote-mep ccm-receive [ mep-id mep-id ] enable

    The MEP is enabled to receive CCMs from the RMEP.

  10. Run test-id test-id [ testid-file ] mep mep-id [ description description ]

    A test instance is configured.

  11. (Optional) Run loss-measure dual-ended local-ratio-threshold mep mep-id upper-limit upper-limit lower-limit lower-limit

    Lower and upper thresholds are set for the near-end frame loss rate in dual-ended frame loss measurement.

  12. (Optional) Run loss-measure dual-ended remote-ratio-threshold mep mep-id upper-limit upper-limit lower-limit lower-limit

    Lower and upper thresholds are set for the far-end frame loss rate in dual-ended frame loss measurement.

  13. Run loss-measure dual-ended continual test-id test-id-value

    Dual-ended frame loss measurement is enabled.

  14. Run commit

    The configuration is committed.

Verifying the Configuration

After completing the configuration, run the display y1731 statistic-type dual-loss [ test-id test-id-value ] [ count count-value ] command on the MEP that initiates dual-ended frame loss measurement to check statistics about dual-ended frame loss.

Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
< Previous topic Next topic >