After configuring basic connectivity fault management (CFM) functions, verify the configurations.
Prerequisites
Basic CFM functions have been configured.
Procedure
- Run the display cfm md [ md-name ] command to check the information about a maintenance domain (MD).
- Run the display cfm ma [ md md-name [ ma ma-name ] ] command to check the information about a maintenance association (MA).
- Run the display cfm mep [ md md-name [ ma ma-name [ mep-id mep-id ] ] ] command to check the information about a local maintenance association end point (MEP).
- Run the display cfm remote-mep [ [ md md-name [ ma ma-name [ mep-id mep-id ] ] ] | [ md md-name [ ma ma-name ] ] cfm-state { disable | down | up } ] command to check the information about a remote maintenance association end point (RMEP).
- Run the display cfm mip [ interface interface-type interface-number | level level ] command to check the information about a maintenance association intermediate point (MIP).
- Run the display cfm default md command to check information about the default MD.
- Run the display cfm mp-info [ interface interface-type interface-number ] [ level md-level ] [ inward | outward ] [ vlan vlanid | vsi vsi-name | no-associated-vlan | mpls l2vc ] command to check information about the CFM objects on a specified interface or virtual local area network (VLAN) or in a specified virtual switching instance (VSI).
- Run the display oam global configuration command to check the MAC address model for maintenance points (MPs).