Configuring an Alarm Threshold for the Number of NEs Connected to a GNE

To prevent a GNE from being overloaded with NEs, configure an alarm threshold for the number of NEs connected to the GNE. When the number of NEs connected to the GNE reaches the alarm threshold, the GNE will send a trap to its interworking NMSs.

Background Information

On a DCN, NMSs use GNEs to manage all common NEs. To prevent a GNE from being overloaded with NEs, configure an alarm threshold for the number of NEs connected to the GNE. When the number of NEs connected to the GNE reaches the alarm threshold, the GNE will send a trap to its interworking NMSs.

Procedure

  1. Run system-view

    The system view is displayed.

  2. Run dcn

    The DCN view is displayed.

  3. Run ne-number alarm threshold threshold

    An alarm threshold is configured for the number of NEs connected to the GNE.

  4. Run commit

    The configuration is committed.