(Optional) Setting the Time During Which the EFM OAM Status of an Interface Remains Down

After EFM OAM is associated with an interface, you can adjust the delay in changing the EFM OAM status of an interface from Down to Up by setting the time during which the EFM OAM status of the interface remains Down, if a link connectivity fault is rectified.

Pre-configuration Tasks

Before setting the time during which the EFM OAM status of an interface remains Down, associate EFM OAM with the interface.

Procedure

  1. Run system-view

    The system view is displayed.

  2. Run interface interface-type interface-number

    The view of the interface at one end of a link is displayed.

  3. Run efm holdup-timer time

    The time during which the EFM OAM status of the interface remains Down is set.

    If the parameter time is not specified, the EFM OAM status of an interface immediately changes from Down to Up when a link connectivity fault is rectified. If the parameter time is specified, the EFM OAM status of an interface changes from Down to Up only when a link connectivity fault is rectified and after the time specified by the parameter time elapses. Setting the parameter time can reduce link flapping. You can run the recover efm-down command to change the EFM OAM status of an interface from Down to Up.

  4. Run commit

    The configuration is committed.