To implement interworking between Huawei and non-Huawei devices, you need to enable the type-132 TLV in LSPs to carry the IP address of only one IS-IS interface on the Huawei device.
By default, on Huawei devices, the type-132 TLV in LSPs carries the IP addresses of all IS-IS interfaces. However, on some non-Huawei devices, the type-132 TLV in LSPs carries the IP address of only one IS-IS interface. To implement interworking between Huawei devices and these non-Huawei devices, enable the type-132 TLV in LSPs to carry the IP address of only one IS-IS interface on the Huawei devices.
The system view is displayed.
An IS-IS process is created, and its view is displayed.
The type-132 TLV in LSPs is enabled to carry the IP address of only one IS-IS interface.
The configuration is committed.